J. Semicond. > 2008, Volume 29 > Issue 7 > 1391-1395

PAPERS

Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation

Dai Qiang, Yu Qi, Rao Qing, Zhou Wei and Yang Mohua

+ Author Affiliations

PDF

Abstract: Based on probability and statistical theory,pulse and step acceleration signal response models of capacitive micro-accelerometer with single-sided driving mode and double-sided driving mode are investigated,respectively,which are established on the assumption that the comb gaps conform to the uniform distribution within a given scope induced by the MEMS processing non-ideality.The precision of the models has been verified by the FEA and monte carlo methods with ANSYS software.The deviation between them is less than 10%.The models suggest that the reliable operation ranges of the accelerometers will decrease 10%~15% when the comb gaps deviate 0~20% from the ideal value.The models can be used in the estimation of the reliable operation ranges of capacitive accelerometers.

Key words: micro-accelerometerscomb gappulse and step signal response modelsreliable operation range

  • Search

    Advanced Search >>

    Article Metrics

    Article views: 2477 Times PDF downloads: 1363 Times Cited by: 0 Times

    History

    Received: 18 August 2015 Revised: 23 January 2008 Online: Published: 01 July 2008

    Catalog

      Email This Article

      User name:
      Email:*请输入正确邮箱
      Code:*验证码错误
      Dai Qiang, Yu Qi, Rao Qing, Zhou Wei, Yang Mohua. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. Journal of Semiconductors, 2008, In Press. Dai Q, Yu Q, Rao Q, Zhou W, Yang M H. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. J. Semicond., 2008, 29(7): 1391.Export: BibTex EndNote
      Citation:
      Dai Qiang, Yu Qi, Rao Qing, Zhou Wei, Yang Mohua. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. Journal of Semiconductors, 2008, In Press.

      Dai Q, Yu Q, Rao Q, Zhou W, Yang M H. Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation[J]. J. Semicond., 2008, 29(7): 1391.
      Export: BibTex EndNote

      Pulse and Step Signal Response Models of Micro-Accelerometers Based on the Comb Gaps Deviation

      • Received Date: 2015-08-18
      • Accepted Date: 2007-11-15
      • Revised Date: 2008-01-23
      • Published Date: 2008-08-01

      Catalog

        /

        DownLoad:  Full-Size Img  PowerPoint
        Return
        Return